F45-magnetic Patented Dual-indicator Flow Meter

Experience the ultimate ease of installation with turning processing – no leaks, effortless adjustment and positioning, a rock-solid flow field, compact size for space-saving installation, our patented dual-pointer design, laser-engraved scale for enhanced flow monitoring convenience!

Brand: LORRIC
Adapter size: 1-1/2", 2"
Applicable fluid: Tap water (PC)/ Unique acid-base solution (PSU)
Working pressure: 6.0kg/cm²
Full Scale Accuracy:5% F.S.
Material: Body-PC, PSU; Float-SS316, Ti, Hastelloy C
 

Catalogue



Principle

The area flow meter calculates flow rates by equating the upward thrust of the fluid, caused by variations in pipe diameter cross-sectional area, with the force of gravity acting on the float from below.

Principle
Patented dual-indicator

Patented dual-indicator

From the user's perspective, LORRIC employs a dual-pointer design to monitor upper and lower limit intervals, enabling users to easily identify the flow status at a glance. Users can simply flick the pointer to instantly set the flow monitoring range.

Laser engraved degree scales

LORRIC precisely calibrates each flow meter at the factory to compensate for float weight variations, ensuring ultimate performance. Unlike competitors using mass printing or stickers, our laser engraving offers both accuracy and durability.

Laser engraved degree scales
Flowmeter scale customization

Flowmeter scale customization

Chemicals vary in specific gravity, affecting float buoyancy. LORRIC offers tailored customization for specific gravity, eliminating the need for on-site height adjustments.

Delicate machining for float

LORRIC leverages 30 years of industry expertise, applying fluid mechanics to refine float design. Using precision CNC machining, each float is crafted with jewelry-like precision, guaranteeing stable monitoring for area flow meters.

Delicate machining for float
Unique Turning Machined Fittings, Smooth Insertion Installation

Unique Turning Machined Fittings, Smooth Insertion Installation

Don't settle for the struggles of traditional intubation joints. LORRIC's innovation brings you turning-processed joints with a specially designed pipe wall, ensuring a silky-smooth installation experience. Say goodbye to tight fits and hello to effortless installation!

The flat joint surface ensures O-ring seal without leakage

Don't settle for subpar joints! While most are injection-molded, resulting in uneven surfaces due to cooling shrinkage, LORRIC's original turning-processed joints offer unmatched quality. With a flawlessly smooth surface, O-ring seal for safety, and zero leakage, choose LORRIC for superior performance!

 
The flat joint surface ensures O-ring seal without leakage
Guide Rail Design

Guide Rail Design

The drawback of float variations due to pipeline turbulence is mitigated by the constraints of the guide rail, which reduces the freedom of movement of the float. This results in more accurate measurements than flow meters without guide rails.

Patent Magnetic Pointer Design

Suitable for monitoring the flow of dark liquids, the patented magnetic pointer design ensures easy installation without leaks, easy adjustment, and precise positioning. The stable flow field, dual pointer design, and laser-engraved scales make flow monitoring more convenient. The connection can be changed to a flange type for increased durability and safety, extending the lifespan of the device.

Patent Magnetic Pointer Design

Please place your order according below information

How to place an order for LORRIC flowmeters? 
  • Select the ideal flow meter based on your material requirements for each component.
  • Please refer to following order example for placing order to LORRIC.
F45-Magnetic Order form
Series F45M PSU F45MH PSU
Applicable Fluid Water and Organic Solvents  When chemicals are corrosive to stainless steel              
Body Material PSU PSU
Float Material AISI 316 Ti / Hastelloy C
Guide Rod Material
O-ring Material
EPDM / VITON
Union Nuts Material UPVC
Guide Rod Bottom Material PP
Scale Range
(L/min)
50 - 300 L/min
50 - 450 L/min
100 - 600 L/min
Adaptor Size and Adaptor Material
1/2"
Male Thread BSPT UPVC / PP
NPT UPVC / PP
Female Thread BSPT UPVC / PP
NPT UPVC / PP
Socket CNS UPVC
JIS UPVC
ANS UPVC
DIN UPVC
Butt Weld  ISO  PPH / PVDF
Socket Weld ISO   PPH / PVDF
2"
Male Thread BSPT UPVC / PP
NPT UPVC / PP
Female Thread BSPT UPVC / PP
NPT UPVC / PP
Socket CNS UPVC
JIS UPVC
ANS UPVC
DIN UPVC
Butt Weld ISO  PPH / PVDF
Socket Weld
 ISO  PPH / PVDF
 Flange  JIS 10K UPVC
  • Liquid flow meters are calibrated for 20°C water. Gas flow meters are calibrated for normal conditions. ( 0°C , 1 atm)
  • All adaptors can be manufactured to order, please contact us for price and lead time. Specs: adaptor 1/2" NPT male/ female thread (UPVC / PP / PSU) type is custom made, please contact us for details. Please refer to the chemical resistance chart for understanding if our flowmeters body and parts are acceptable for your solution.
  • Above temperature information is for reference only and may not be applicable for all environments.
  • Above flow rate range and materials is for standard specs. Please choose proper products according to your usage and environment conditions. You are welcome to contact us directly for any requests and advice.
  • Product Size

     

    Adapter Spec A / F*
    B / G*
    C / H*
    D E 接管式
    重量(g)
    1-1/2"Male Thread 346 187 79.5 109 127

    1400











    1-1/2"Female Thread 347 187 80 109 127
    1-1/2"ASTM 347 187 80 109 127
    1-1/2"JIS 345 187 79 109 127
    2"Male Thread 345 187 79 109 127
    2"Female Thread 345 187 79 109 127
    2"CNS 357 187 85 109 127
    2"ASTM 345 187 79 109 127
    2"JIS 357 187 85 109 127
    PPOD72.7
    ID60.1
    305 187 59 109 127
    PPOD60
    ID48.9
    345 187 79 109 127
    法蘭式 2" 390 187 155 - -

    Three easy steps! Effortlessly install the rotameter!

    Step1
    Step1

    Ensure the main line is vertically installed and that there is ample space to accommodate the flow meter size.

    Step2
    Step2

    Loosen the upper and lower interfaces, including the nuts, and affix them to the pipe using adhesive until the glue sets.

    Step3
    Step3

    Position the body in the center and secure the upper and lower unions.

     

    Applications
    PCBs

    PCBs

    Flow meters in PCB electroplating, developing, and etching processes monitor precise chemical and cleaning fluid flow; nozzles control chemical coating and rinsing

    Wastewater Treatment

    Wastewater Treatment

    Flow meters monitor the flow of inlet and outlet water, enhancing treatment efficiency and accuracy; nzzles spray chemicals in wastewater treatment, meeting environmental standards

    Purified Water Industries

    Purified Water Industries

    Flow meters monitor water usage at each stage to control process efficiency; nozzles optimize water spray to ensure water purification efficiency and reduce treatment costs

    Electroplating

    Electroplating

    Flow meter controls the flow of chemical liquids, ensuring a uniform coating for quality assurance; the nozzle ensuring even coating and consistent quality during electroplating

    • Cleaning: Containers, Filters, Dust, Gravel, Metals, Metal Parts, Machinery, Various Containers, High Pressure Cleaning, Wet Processing Display Pane, machine tool cleaning, etc.
    • Cooling: gas, tank, machinery, roof etc.
    • Dispersion: Humidifying, Chemicals (etching solution, lubricants, insect repellent, etc.), water curtain (fire, dust, deodorization etc.).

    Working with sulfuric acid, caustic soda, or unique specialty chemicals? Explore our tailored specific gravity scale customization services

    Diverse chemicals, varying specific gravity. LORRIC offers bespoke specific gravity customization to match your chemical needs. No more on-site manual height adjustments!

    Working with sulfuric acid, caustic soda, or unique specialty chemicals? Explore our tailored specific gravity scale customization services

    What we customize

    • Different measure unit (LPM, LPH, CMPM and more)
    • Main and secondary scale
    • Different liquid proportion
    • Different gas molecular weights
    • Different measuring ranges
    What we customize

    Customizing Flow Meter Scales: A Step-by-Step Guide

    • Range of customized flow capacity should be stayed within the capacity of existing products.
    • Customizable capacity will be affected by customization of proportion and viscosity, please contact us directly for this service.
    • To customize too compressed flow scales is not suggested, and leads difficulty of on-site observation

    Products you may also like
    Related articles