F32b M Size Pipe Size ½-1" Flow Meter with Limit Switch

Experience the ultimate ease of installation with turning processing – no leaks, effortless adjustment and positioning, a rock-solid flow field, compact size for space-saving installation, our patented dual-pointer design, laser-engraved scale for enhanced flow monitoring convenience!

Brand: LORRIC
Adapter size: 1/2", 3/4", 1"
Applicable fluid: Tap water (PC)/ Unique acid-base solution (PSU)
Working pressure: 6.0kg/cm²
Full Scale Accuracy:5% F.S.
Material: Body-PC, PSU; Float-PVC,PP,PVDF,Teflon
 

Catalogue



Principle

The area flow meter calculates flow rates by equating the upward thrust of the fluid, caused by variations in pipe diameter cross-sectional area, with the force of gravity acting on the float from below.

Principle
Patented dual-indicator

Patented dual-indicator

From the user's perspective, LORRIC employs a dual-pointer design to monitor upper and lower limit intervals, enabling users to easily identify the flow status at a glance. Users can simply flick the pointer to instantly set the flow monitoring range.

Laser engraved degree scales

LORRIC precisely calibrates each flow meter at the factory to compensate for float weight variations, ensuring ultimate performance. Unlike competitors using mass printing or stickers, our laser engraving offers both accuracy and durability.

Laser engraved degree scales
Flowmeter scale customization

Flowmeter scale customization

Chemicals vary in specific gravity, affecting float buoyancy. LORRIC offers tailored customization for specific gravity, eliminating the need for on-site height adjustments.

Unique Turning Machined Fittings, Smooth Insertion Installation

Don't settle for the struggles of traditional intubation joints. LORRIC's innovation brings you turning-processed joints with a specially designed pipe wall, ensuring a silky-smooth installation experience. Say goodbye to tight fits and hello to effortless installation!

Unique Turning Machined Fittings, Smooth Insertion Installation
Flat Contact Surfaces on Fittings, Paired with Oring for Leak-Proof Assurance

Flat Contact Surfaces on Fittings, Paired with Oring for Leak-Proof Assurance

Most market-available fittings are injection molded, leading to wavy surfaces due to cooling shrinkage. LORRIC uniquely produces fittings by turning, resulting in a smooth surface without depressions, paired with an Oring seal for a worry-free, leak-proof experience.

 

No-Guide-Rail Design

The float is made of special materials, particularly suitable for solutions corrosive to metals and environments requiring high chemical resistance.

No-Guide-Rail Design

Please place your order according below information.

How to place an order for LORRIC flowmeters?
  • Select the ideal flow meter based on your material requirements for each component.
  • Please refer to following order example for placing order to LORRIC.
F32B Order form
Series F32B PSU F32B w/ Inductor PSU
Applicable Fluid  Liquid (Highly corrosive)
Body Material  PSU
Float Material
PP
O-ring Materia
EPDM / VITON
Union Nuts Material UPVC
Guide Rod Bottom Material PP
Scale Rang
(L/min)
9 - 18 L/min
16 - 32 L/min
30 - 60 L/min
45 - 90 L/min
Adaptor Size and Adaptor Material
1/2"
Male Thread BSPT UPVC / PVDF
NPT UPVC / PVDF
Female Thread BSPT UPVC / PVDF
NPT UPVC / PVDF
Socket CNS UPVC
JIS UPVC
ANS UPVC
DIN UPVC
Butt Weld  ISO PPH / PVDF
Socket Weld ISO  PPH / PVDF
3/4"
Male Thread BSPT UPVC / PVDF
NPT UPVC / PVDF
Female Thread BSPT UPVC / PVDF
NPT UPVC / PVDF
Socket CNS UPVC
JIS UPVC
ANS UPVC
DIN UPVC
Butt Weld  ISO PPH / PVDF
Socket Weld ISO  PPH / PVDF
1"
Male Thread BSPT UPVC / PVDF
NPT UPVC / PVDF
Female Thread BSPT UPVC / PVDF
NPT UPVC / PVDF
Socket CNS UPVC
JIS UPVC
ANS UPVC
DIN UPVC
Butt Weld  ISO PPH / PVDF
Socket Weld ISO  PPH / PVDF
  • Liquid flow meters are calibrated for 20°C water. Gas flow meters are calibrated for normal conditions. ( 0°C , 1 atm)
  • All adaptors can be manufactured to order, please contact us for price and lead time. Specs: adaptor 1/2" NPT male/ female thread (UPVC / PP / PSU) type is custom made, please contact us for details. Please refer to the chemical resistance chart for understanding if our flowmeters body and parts are acceptable for your solution.
  • Above temperature information is for reference only and may not be applicable for all environments.
  • Above flow rate range and materials is for standard specs. Please choose proper products according to your usage and environment conditions. You are welcome to contact us directly for any requests and advice.
  • Our company refrains from offering model recommendations or suggestions, as diverse industries have unique application scopes and design conditions. We encourage you to select the most suitable model based on your specific design conditions.

Product Size

單位:mm

接頭規格 A B C D E 接管式
重量(g)
1"Male Thread 210 111 49.5 60 64

190
1"Female Thread 210 111 49.5 60 64
1"CNS 197 111 43 60 64
1"ASTM 197 111 43 60 64
1"JIS 195 111 42 60 64
3/4"Male Thread 196 111 42.5 60 64
3/4"Female Thread 211 111 50 60 64
CNS 199 111 44 60 64
3/4"ASTM 193 111 41 60 64
3/4"JIS 200 111 44.5 60 64
3/4"DIN 199 111 44 60 64
3/4"DIN
管壁厚
195 111 42 60 64
1/2"JIS MIN 192 111 40.5 60 64
1/2"ASTM 191 111 40 60 64
1/2"JIS 190 111 39.5 60 64
1/2"DIN 189 171 39 60 64
PP OD40.4
ID34
197 111 43 60 64
PP OD33
ID25.2
193 111 41 60 64
 

Three easy steps! Effortlessly install the rotameter!

Step1
Step1

Ensure the main line is vertically installed and that there is ample space to accommodate the flow meter size.

Step2
Step2

Loosen the upper and lower interfaces, including the nuts, and affix them to the pipe using adhesive until the glue sets.

Step3
Step3

Position the body in the center and secure the upper and lower unions.

 

Applications
PCBs

PCBs

Flow meters in PCB electroplating, developing, and etching processes monitor precise chemical and cleaning fluid flow; nozzles control chemical coating and rinsing

Wastewater Treatment

Wastewater Treatment

Flow meters monitor the flow of inlet and outlet water, enhancing treatment efficiency and accuracy; nzzles spray chemicals in wastewater treatment, meeting environmental standards

Purified Water Industries

Purified Water Industries

Flow meters monitor water usage at each stage to control process efficiency; nozzles optimize water spray to ensure water purification efficiency and reduce treatment costs

  • Cleaning: Containers, Filters, Dust, Gravel, Metals, Metal Parts, Machinery, Various Containers, High Pressure Cleaning, Wet Processing Display Pane, machine tool cleaning, etc.
  • Cooling: gas, tank, machinery, roof etc.
  • Dispersion: Humidifying, Chemicals (etching solution, lubricants, insect repellent, etc.), water curtain (fire, dust, deodorization etc.).

Working with sulfuric acid, caustic soda, or unique specialty chemicals? Explore our tailored specific gravity scale customization services

Diverse chemicals, varying specific gravity. LORRIC offers bespoke specific gravity customization to match your chemical needs. No more on-site manual height adjustments!

Working with sulfuric acid, caustic soda, or unique specialty chemicals? Explore our tailored specific gravity scale customization services

What we customize

  • Different measure unit (LPM, LPH, CMPM and more)
  • Main and secondary scale
  • Different liquid proportion
  • Different gas molecular weights
  • Different measuring ranges
What we customize

Customizing Flow Meter Scales: A Step-by-Step Guide

  • Range of customized flow capacity should be stayed within the capacity of existing products.
  • Customizable capacity will be affected by customization of proportion and viscosity, please contact us directly for this service.
  • To customize too compressed flow scales is not suggested, and leads difficulty of on-site observation

Products you may also like
Related articles