FU-ES EchoSense クランプオン超音波流量計

台湾製クランプオン型超音波流量計。特許取得済みのワンクリック設定技術を搭載。革新的なクランプオン式取り付けにより、わずか3分で3ステップの簡単操作を実現。市場でのスピードと利便性の新基準を設定します。

製品仕様

対応配管サイズ: 1/2~3インチ
流体温度: 0~85°C(表面に氷がない状態)
対応流体: 水、油、化学薬品
測定精度: ±3%(F.S.の10~100%で)
防水性能: IP66
電源要件: DC 12V~36V
表示流量: 瞬時流量/積算流量
入出力: アナログ出力(16ビット 4-20mA、自給電源付)
Modbus RTU RS485
2線式光電スイッチ信号(NPN/PNP対応)

Catalogue MANUAL



Clamp on Flow Meter

The clamp on ultrasonic flow meter measures by attaching sensors to both sides of the pipe, requiring no cutting or interruption of flow during installation—ideal for situations where downtime is not an option.
This non-invasive method is ideal for contamination-free measurements in semiconductor processes, PCB manufacturing, and water treatment, offering high linearity and consistent accuracy at all flow rates.

Clamp on Flow Meter
ToF (Time of Flight) Principle

ToF (Time of Flight) Principle

Using the formula Flow Rate = Cross-Sectional Area × Flow Velocity, accurate flow measurement depends on precisely measuring fluid velocity. The FU-ES ultrasonic flow meter, with EchoSense technology, calculates velocity by measuring the time difference of ultrasonic waves traveling with and against the flow (Time of Flight).
As shown in the diagram, ultrasonic signals move faster with the flow (A to B) and slower against it (B to A) due to the fluid's influence on wave speed. By measuring this time difference, the flow velocity is determined, and combined with the pipe's cross-sectional area, the flow rate can be accurately calculated.
Learn more: How to Calculate Flowrate

Applicable to variety of fluids, pipe materials and diameters

EchoSense ultrasonic flow meter is versatile, working with water, oil, and chemicals. It's compatible with stainless steel, PVC, and even PP, PVDF piping materials. With applications ranging from 1/2-inch to 3-inch pipes.

Applicable to variety of fluids, pipe materials and diameters
Say goodbye to costly ultra sonic gel; Welcome time and cost savings

Say goodbye to costly ultra sonic gel; Welcome time and cost savings

LORRIC's "ultra sonic gasket pad" is a hassle-free solution that saves you both time and money. No more dealing with the mess and inconvenience of ultrasonic gel.

Complete all settings in 1 click

With EchoSense technology, forget about worrying over pipe materials, inner and outer diameters, thickness, liquid speed of sound, probe placement, and installation complexities. With just one click, we've simplified it all, making installation and setup a breeze. Say goodbye to the hassle!

Complete all settings in 1 click
Automatic Pipe Specification Matching

Automatic Pipe Specification Matching

EchoSense technology features a built-in database of common pipe specifications, including PVC, PP, PVDF, and stainless steel. After installation, one click matches the installed pipe with the database, automatically setting material, outer diameter, and wall thickness. This streamlines installation by removing manual configuration and reducing errors, solving the issue of uncertain pipe specs in traditional setups.

Remarkable measurement accuracy

LORRIC's exclusive algorithm maintains high precision, earning Germany's TrigasFI certification. Test charts show FU-ES measurement accuracy between ±3.0% OR for 10%-100% of full scale (F.S.) and ±0.3% F.S. for 0%-10% of F.S. For a DN25 pipe (3-300LPM range), a 100LPM reading (10%-100%) has a ±3.0% error (97-103). A 20LPM reading (0%-10%) has a ±0.3% error (19.91-20.09).

Remarkable measurement accuracy
Multiple Communication Outputs

Multiple Communication Outputs

FU-ES supports various communication modes like Analog output with self-powered 16-bit 4-20mA, Modbus RTU RS485, 2-wire photoelectric switch signal (compatible with NPN/PNP). No need for additional communication modules – we've got you covered!  
Learn more:
What is Analog Output
What is Modbus RTU RS485
What is Switch Signal

Detect problems instantly and intelligently with this ultrasonic flow meter using automatic sensing environment

Unlock Intelligent Environmental Monitoring with EchoSense! Our cutting-edge algorithm delivers real-time insights into installation issues, pipe saturation, bubbles, impurities, and more. Stay in control of your pipeline's health and troubleshoot issues instantly!

Probes dislocated
Probes dislocated

Probes dislocated due to installation issues.

Low fluid levels and excessive bubbles
Low fluid levels and excessive bubbles

Signal problems arise from low fluid levels and excessive bubbles in the pipe.

Excessive impurities
Excessive impurities

Signal problems arise from excessive impurities in the pipe.

Dual LCD/LED screens for easy traffic and equipment status monitoring

  • High-brightness large LED screen for easy long-distance flow number reading.
  • LCD screen backlight with three-color warning light signal for visual monitoring of flow meter's normal and abnormal conditions.
Dual LCD/LED screens for easy traffic and equipment status monitoring
Vertically and Horizontally Installable

Vertically and Horizontally Installable

The EchoSense ultrasonic flow meter screen features a square design, allowing for both vertical and horizontal installation to suit different usage scenarios. When installing at different angles, simply remove the screws on the four sides of the screen, rotate the screen 90 degrees, and reattach the screws. The display will easily adjust to the new orientation.

Elevate chemical resistance with our engineering plastic housing for the flowmeter.

Experience the Power of FU-ES! Crafted from robust engineering plastics like Nylon, PPS, and PEEK, its outer body boasts incredible strength. Inside, reinforced with 304 stainless steel, ensuring unmatched structural rigidity while prioritizing chemical resistance and product longevity.

Elevate chemical resistance with our engineering plastic housing for the flowmeter.
 Taiwan Excellence Award 2025 and iF Design Award 2024

Taiwan Excellence Award 2025 and iF Design Award 2024

LORRIC, in collaboration with CRE8, developed the EchoSense Ultrasonic Flow Meter, earning the 2024 iF Design Award and the 2025 Taiwan Excellence Award. These honors highlight its innovation, functionality, aesthetics, UX/UI, and sustainability.  
➜ CRE8 WINS 3 MORE ESTEEMED IF DESIGN AWARDS
➜ iF Design Award LORRIC EchoSense Ultrasonic Flow meter
➜ Taiwan Excellence FU-ES EchoSense

Spec

FU-ES015 FU-ES020 FU-ES025 FU-ES032 FU-ES040 FU-ES050 FU-ES065 FU-ES075
Installation method  Outside the pipe (clamp-on type)
Applicable diameter 20-22
mm
25-27.2
mm
32-34
mm
38-42.16
mm
48-50
mm
60-63
mm
73-76.3
mm
88.9-90
mm
0.79-0.87
inch
0.83-0.87
inch
1.26-1.34
inch
1.5-1.66
inch
1.89-1.97
inch
2.36-2.48
inch
2.87-3
inch
3.5-3.54
inch
Applicable pipe material Metal pipe, Plastic pipe (UPVC, PPH, PVDF)
Applicable fluid Various liquids (no impurities or air bubbles)
Applicable fluid temperature 0 ~ 85°C (no ice on the piping surface)
Velocity range ±0.3 to 6.0 m/s recommended, ±0.1 to 10m/s measurable
Flow range 1.5-120
LPM
2-200
LPM
3-300
LPM
5-470
LPM
8-770
LPM
13-1320
LPM
22-1670
LPM
30-1870
LPM
0.4-31.7 gpm 0.53-52.83 gpm 0.53-52.83 gpm 1.32-124.16 gpm 2.11-203.41 gpm 3.43-348.71 gpm 5.81-441.17 gpm 7.93-494 gpm
Language
English, Traditional and Simplified Chinese (others can be customized)
Units Metric - Meters, Cubic Meters, Liters
Time - Seconds, Minutes, Hours, Days
Imperial - Feet, Cubic Feet, UK gallon, US gallon
Display mode Dual screen display: 5-digit LED + 3-color backlight, 3-line 16-character LCD
Display update cycle 0.5s、1s
Measurement Accuracy ±3.0% RD at 10% to 100% of F.S.
±0.3% F.S. at 0% to 10% of F.S.*
Display resolution Maximum resolution 0.0001 (finest)
Power demand DC 12V to 36V
Power I/O Connector M12 8-pin connector (2 meters long)
Input/Output Analog output with self-powered 16-bit 4-20mA
Modbus RTU RS485
Two-wire optocoupler switch signal (with 2 meters long signal line)
Consumption current <200mA@12V when starting up and working stably (not included in the communication current)
Protection circuit Power reverse connection protection, Power surge protection
Waterproof level IP66**
Ambient temperature -10 ~ 60°C (no freezing)
Relative humidity 35~ 85%RH (non-condensing)
Material PPS+GF, PEEK, NBR, Silicon, PA66+GF, PC+GF, SS304, PMMA
Weight (g)
770
770
785 800 1390 1540 1580 1650
* The measurement accuracy is established in a controlled laboratory environment where the pipe and fluid conditions are set and the instrument is calibrated to zero before conducting tests at 25°C. Although statistical results are obtained under these conditions, there may be variances in accuracy when used in customer environments.
** Incorrect installation when rotating the screen by loosening the screws around it may affect the IP66 waterproof protection.

Size

FU-ES015 / FU-ES020 / FU-ES025 / FU-ES032

Unit:mm

Model A B C D E F
FU-ES015 169.85 64 79 115 120.53 54
FU-ES020 169.85 64 79 115 124.02 54
FU-ES025 169.85 64 79 115 133.52 54
FU-ES032 169.85 64 79 115 143.02 54

FU-ES040 / FU-ES050 / FU-ES065 / FU-ES075

Unit:mm

Model A B C D E F
FU-ES040 184.90 64 125.22 164.12 53.50 69.50
FU-ES050 184.90 64 125.30 178.12 53.50 69.50
FU-ES065 184.90 64 126.87 193.12 53.50 69.50
FU-ES075 184.90 64 128.55 207.12 53.50 69.50

Cable Head Size 

Applications

Semiconductor

Semiconductor

Flow meters monitor chemical liquids and pure water treatment fluids supply; nozzles control the spraying of chemical liquids to ensure process purity and stability.

PCBs

PCBs

Flow meters in PCB electroplating, developing, and etching processes monitor precise chemical and cleaning fluid flow; nozzles control chemical coating and rinsing

Wastewater Treatment

Wastewater Treatment

Flow meters monitor the flow of inlet and outlet water, enhancing treatment efficiency and accuracy; nzzles spray chemicals in wastewater treatment, meeting environmental standards

Purified Water Industries

Purified Water Industries

Flow meters monitor water usage at each stage to control process efficiency; nozzles optimize water spray to ensure water purification efficiency and reduce treatment costs

Car Wash

Car Wash

Flow meters ensure cleaning efficiency and reduce water wastage; nozzles uniformly distribute water, enhancing the cleaning effect while simultaneously reducing water consumption

AC

AC

Flow meters monitor and control cooling and hot water flows, tracking chiller energy use; nozzles balance water flow in these systems, enhancing efficiency

Steel Industries

Steel Industries

Flow meters monitor cooling water and gas flow, ensuring accuracy and optimal efficiency; nozzles precisely control chemical liquid spraying, making even coating and stable quality

10-Minute Guide to Installing and Setting Up the EchoSense Clamp-On Ultrasonic Flow Meter

 

Products you may also like
Related articles